Community Fire Equipment, 7 Prices Switch Road, Vernon, NJ, 07462, 810-610-5600, 888-493-7634, Fax: 973-764-2434

Products
Service
Training
Contact


Homeland Security


   
     
Advantage® 1000 CBA RCA Gas Mask

A clean, simplified respirator with Hycar facepiece (based on a proven facepiece design developed for the U.S.Armed forces) that’s up to 40% lighter than conventional full-face respirators and gives high performance, customized fit, comfort, economy, and user acceptance.
• Flexible, 1-piece polyurethane lens with wide field of vision is bonded to durable Hycar rubber facepiece
• Dual-canister mount (bayonet mount) allows weapon sighting from either shoulder
• Fully elastic, 6-point head harness promotes easy on-off, easy adjustment, no hair pulling
• Standard nosecup helps eliminate lens fogging
• Standard mechanical speaking diaphragm included, or add MSA’s optional ESP Communications System
• NIOSH-approved (No.TC-14G-0235) for protection against chloroacetophenone (CN), chlorobenzylidene (CS), P100 particulate efficiency level, and particulates
   
Advantage® 3200 CBA-RCA Gas Mask

The Advantage 3200 CBA-RCA (Chemical Biological Agent-Riot Control Agent) Gas Mask is based on MSA’s already very popular industrial Advantage 3200 Respirator. It features a soft, pliable silicone facepiece, yet serves as an economical, cost-effective alternative to more expensive Gas Masks for this application.
• New 1-piece polycarbonate wraparound lens, engineered to be optically correct to eliminate distortion, promote superior visibility and peripheral vision.
• Soft, pliable silicone facepiece with proven Advantage respirator seal that instantly conforms to wearer’s face.
• Choice of head harness:
- New European-style Advantage head harness with easy on/off
pre-adjustable straps, dons like a catcher’s mask, or
- More traditional Hycar rubber head harness
• Dual-canister mount (bayonet mount) allows weapon sighting from either shoulder.
• Proven exceptionally comfortable, lightweight, stable, and low maintenance
• Very low breathing resistance.
• Standard nosecup to help eliminate lens fogging.
   
Millennium® Chemical-Biological Gas Mask

A Hycar version of the reliable military-style gas mask (MCU-2/P Mask, used by the U.S. Air Force in Desert Storm) that combines high performance, customized fit, comfort and cost efficiency.
• Flexible, 1-piece polyurethane lens with wide field of vision is bonded to durable Hycar rubber facepiece
• Dual-canister mount (NATO 40mm thread) allows weapon sighting from either shoulder
• Drinking tube provides connection for fluid ingestion in contamination atmospheres
• Fully elastic, 6-point head harness promotes easy on-off, easy adjustment, no hair pulling
• Internal nosecup with 2 check valves deflects air from the lens, reduces fogging
• Standard mechanical speaking diaphragm included, or add MSA’s optional ESP® Communications System
   
Blackhawk™ Tactical Air Mask (SCBA)
All-black Hycar or silicone Ultra Elite ® facepiece available in three sizes, Nightfighter Heads-Up-Display mounting bracket, and SpeeD-ON® Kevlar facepiece harness. Firehawk Push-to-Connect Mask-Mounted regulator has neoprene intermediate pressure hose, variable flow bypass system and purge button. Nightfighter Heads-Up-Display (HUD) low-pressure warning device and cylinder pressure gauge system consists of a transmitter mounted on a gauge line and facepiece-mounted receiver. Features glass-reinforced composite backplate, harness with flame-and-heat-resistant (FHR) Kevlar waist belt, shoulder straps, pull strap, optional FHR shoulder pads, lumbar pad, FHR chest strap and an adjustable Kevlar cylinder retention strap with over-center latching system. A black FHR cylinder shroud encompassing cylinder and air mask components eliminates reflections that would compromise concealment. Choice of low-pressure L-30 Stealth , or high-pressure H-30 Stealth, H-45 Low-Profile Stealth or H-60 Stealth carbon fiber cylinders. Optional shoulder-mounted Quick-Fill® system for rapid cylinder filling in tactical situations. Work-line accessory enabling SCBA connection to portable air-supply system and hard or soft storage carrying case available.
  • Safety, Simplicity and Reliability
  • Designed for Stealth Operations (Law Enforcement)
  • Firehawk MMR for ease of use and ergonomics
  • Noise Emitting devices have been replaced with the Heads-Up Display for cylinder status
  • Optional Kevlar Harness Assembly
     
Ultra Elite® CBRN Gas Mask
  • Safety
    • Super-soft black Hycar rubber exceeds the CBRN permeation requirements
    • Large lens with 83% unimpeded vision
    • Centrally located inlet port for secure,comfortable fit and feel
    • Centrally located mechanical speaking diaphragm for clear communications
    • Optional ClearCommand® Amplifier for increased communication capabilities
  • Simplicity
    • Available with 5-point rubber or SpeeD-ON® head harness
    • Identical sealing surfaces for both SCBA and Gas Mask facepieces-eliminating the need for redundant fit testing
    • Simplified respiratory protection training program
  • Reliability
    • The Ultra Elite facepiece is fire-service proven,with over a decade of trusted use
    • MSA has been making gas masks since World War I
    • Largest supplier of gas masks to the law enforcement market
     
HAZMATCAD™ and HAZMATCAD™ Plus Hazardous Material Chemical Agent Detectors
The HAZMATCAD Plus Chemical Agent Detector detects both chemical warfare agents and selected toxic industrial chemicals (TICs). Both units are ruggedly constructed, compact and lightweight. They are also extremely easy to use, requiring no prior training. A single key press begins automatic sampling and analysis. Audible and visual alarm messages provide clear and simple alarm condition display. Offers self-diagnostic check during rapid warm-up, alphanumeric display with LED alarms and 8-12 hour operation with rechargeable lithium ion batteries. Vapor diffusion check source verifies system performance. RS 232 and IrDA communication ports store up to eight hours of data. The inlet design protects against dust and particulate. Kits include a battery charger, belt clip, two Sony long-life lithium ion rechargeable batteries, a waterproof carrying case, vapor check source and operating manual.
  • Compact, lightweight and portable
  • Alphanumeric display with LED alarms
  • Dual-Mode SAW Operation—fast or high sensitivity
  • Operates between eight and 12 hours on rechargeable Li-Ion batteries
  • RS-232 and IrDA communication ports; stores up to eight hours of data

Website created by Billy Gallagher
© Community Fire Equipment